Intel SSR212MC2 Enclosure

Top  Previous  Next

The software now enumerates Intel's McKay Creek family of enclosures.  This product is also known as the Intel Storage Server SSR212MC2. Unlike the bundled software that Intel supplies, smartmon-ux supports Solaris, all 64-bit windows variants, and numerous 32/64-bit LINUX variants.  SMARTMon-UX is capable of providing full control, configuration, and monitoring.  It will also provide flexibility to use "unsupported" peripherals and controllers, let you manually or automatically manipulate the LEDs and audible alarms using the standard -EPxx family commands.

 

Below is the full SES dump as seen on a system running a custom 64-bit kernel

(Note: We discovered a firmware bug in build B55 of the firmware.  As of June 2008, they have acknowledge the defect, and are working on a fix. Specifically, the system is not reporting temperature for CPU1).

 

# /etc/smartmon-ux -E+ /dev/sg13

SMARTMon-UX [Release 1.36, Build 30-JUN-2008] - Copyright 2001-2008 SANtools(R), Inc. http://www.SANtools.com

Enclosure fault on Intel    SSR212MC         WWN=50-05-0C-C1-01-AB-C7-00:

ArrayDevice #0 OK SelID=00h [Row=1 Col=1]

ArrayDevice #1 OK SelID=00h [Row=1 Col=2]

ArrayDevice #2 OK SelID=00h [Row=1 Col=3]

ArrayDevice #3 OK SelID=00h [Row=1 Col=4]

ArrayDevice #4 OK SelID=00h [Row=2 Col=1]

ArrayDevice #5 OK SelID=00h [Row=2 Col=2]

ArrayDevice #6 OK SelID=00h [Row=2 Col=3]

ArrayDevice #7 OK SelID=00h [Row=2 Col=4]

ArrayDevice #8 OK SelID=00h [Row=3 Col=1]

ArrayDevice #9 OK SelID=00h [Row=3 Col=2]

ArrayDevice #10 OK SelID=00h [Row=3 Col=3]

ArrayDevice #11 OK SelID=00h [Row=3 Col=4]

Power Supply #0 OK

Power Supply #1 Not Installed

Cooling Element #0 OK fan at 80% speed [actual speed 9300 rpm]

Cooling Element #1 OK fan at 80% speed [actual speed 9900 rpm]

Cooling Element #2 OK fan at 80% speed [actual speed 9100 rpm]

Cooling Element #3 OK fan at 80% speed [actual speed 10000 rpm]

Cooling Element #4 OK fan at 80% speed [actual speed 9300 rpm]

Cooling Element #5 OK fan at 80% speed [actual speed 10000 rpm]

Cooling Element #6 OK fan at 80% speed [actual speed 9400 rpm]

Cooling Element #7 OK fan at 90% speed [actual speed 10500 rpm]

Cooling Element #8 OK fan at 80% speed [actual speed 9100 rpm]

Cooling Element #9 OK fan at 80% speed [actual speed 10000 rpm]

Temperature Sensor #0 OK 84F/29C

Temperature Sensor #1 OK 79F/26C

Temperature Sensor #2 OK 99F/37C below cpu threshold

Temperature Sensor #3 Not Installed

Temperature Sensor #4 OK 97F/36C

Temperature Sensor #5 OK 79F/26C below cpu threshold

DoorLock #0 OK LOCKED

Audible Alarm #0 OK ENABLED

SESElectronics Processor #0 OK [PASSIVE]

SESElectronics Processor #1 OK [PASSIVE]

SESElectronics Processor #2 OK [PASSIVE]

SESElectronics Processor #3 OK [PASSIVE]

SESElectronics Processor #4 OK [PASSIVE]

SESElectronics Processor #5 OK [PASSIVE]

SESElectronics Processor #6 OK [PASSIVE]

Display Unit #0 OK OFF [Amber fault LED]

Display Unit #1 OK OFF [Blue chassis ID LED]

SAS Connector #0 N/A

T10 Compliance #0 OK [T10 compliance=OFF, Acoustic Mode=Unsupported]

SES Firmware Revision:        "3155"

 

Element Descriptors Information

Array Device (0)                         "Dk0"

Array Device (1)                         "Dk1"

Array Device (2)                         "Dk2"

Array Device (3)                         "Dk3"

Array Device (4)                         "Dk4"

Array Device (5)                         "Dk5"

Array Device (6)                         "Dk6"

Array Device (7)                         "Dk7"

Array Device (8)                         "Dk8"

Array Device (9)                         "Dk9"

Array Device (10)                        "Dk10"

Array Device (11)                        "Dk11"

Power Supply (0)                         "PSUL"

Power Supply (1)                         "PSUU"

Cooling Element (0)                      "Fn0"

Cooling Element (1)                      "Fn1"

Cooling Element (2)                      "Fn2"

Cooling Element (3)                      "Fn3"

Cooling Element (4)                      "Fn4"

Cooling Element (5)                      "Fn5"

Cooling Element (6)                      "Fn6"

Cooling Element (7)                      "Fn7"

Cooling Element (8)                      "Fn8"

Cooling Element (9)                      "Fn9"

Temperature Sensor (0)                   "Int"

Temperature Sensor (1)                   "Ext"

Temperature Sensor (2)                   "CPU0"

Temperature Sensor (3)                   "CPU1"

Temperature Sensor (4)                   "Mobo"

Temperature Sensor (5)                   "DIMM"

SESElectronics Processor (0)             "EMC/CPLD Ver-0x3-0x1"

SESElectronics Processor (1)             "01A"

SESElectronics Processor (2)             "Intel Starlake S5000PSL"

SESElectronics Processor (3)             "Woodcrest Xeon"

SESElectronics Processor (4)             "Woodcrest Xeon"

SESElectronics Processor (5)             "IntelSRCSAS144E"

SESElectronics Processor (6)             "DIMM"

Display Unit (0)                         "Flt"

Display Unit (1)                         "ID"

SAS Expander (0)                         "Exp"

T10 Compliance (0)                       "T10"

 

 

Threshold Information                   Warning Range   Critical Range

Temperature Sensor #0:                    16 - 42          16 - 44

Temperature Sensor #1:                     8 - 33           8 - 35

Temperature Sensor #2:                  158 - 253        142 - 254

Temperature Sensor #3:                  158 - 253        142 - 254

Temperature Sensor #4:                    16 - 63          16 - 65

Temperature Sensor #5:                  158 - 253        142 - 254

 

Module Locations - Front View

Col-1     Col-2     Col-3     Col-4

+--------------------------------------+

|SLOT 00 | SLOT 01 | SLOT 02 | SLOT 03 | Row-1

|SLOT 04 | SLOT 05 | SLOT 06 | SLOT 07 | Row-2

|SLOT 08 | SLOT 09 | SLOT 10 | SLOT 11 | Row-3

+--------------------------------------+

   Module Locations - Rear View

+--------------------------------------+

| PSU1/ Cooling    | Rest of system IO |

| PSU0/ Cooling    | ports from Mobo   |

+--------------------------------------+

 

Internal Device Information

Bay  Type     SAS Expander Address       SAS Device Address

------------------------------------------------------------

 1  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-01

 2  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-02

 3  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-03

 4  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-04

 5  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-05

 6  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-06

 7  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-07

 8  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-08

 9  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-09

10  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-0A

11  SATA  50-05-0C-C1-01-AB-C7-00  50-05-0C-C1-01-AB-C7-0B