Example Mode Page Dump - SCSI Tape

Top  Previous  Next

The results below were run under Windows XP using a Tandberg SLR7 Tape

 

C>\scratch>smartmon-ux -J \\.\TAPE0

SMARTMon-UX [Release 1.41, Build  1-NOV-2009] - Copyright 2001-2009 SANtools(R), Inc. http://www.SANtools.com

Discovered TANDBERG SLR7 S/N "SN007005396" on \\.\TAPE0 (tape) [Bus/Port/ID.LUN=0/3/12.0]

Read-Write Error Recovery                : Page [01h] (Factory, Current, Saved)

Transfer block (TB)                     : 0, 0, 0 {R/O}

Enable early recovery (EER)             : 1, 1, 1 {R/O}

Post error (PER)                        : 0, 0, 0 {R/O}

Disable transfer on error (DTE)         : 0, 0, 0 {R/O}

Disable correction (DCR)                : 0, 0, 0

Read retry count (RRC)                  : 24, 24, 24

Write Retry Count (WRC)                 : 16, 16, 16

 

Disconnect-Reconnect                     : Page [02h] (Factory, Current, Saved)

Buffer full ratio (BFR)                 : 16, 16, 16

Buffer empty ratio (BER)                : 16, 16, 16

Bus inactivity limit (BIL)              : 0, 0, 0 {R/O}

Disconnect time limit (DTL)             : 0, 0, 0 {R/O}

Connect time limit (CTL)                : 0, 0, 0 {R/O}

Maximum burst size (MBS)                : 0, 0, 0

Enable modify data pointers (EMDP)      : 0, 0, 0 {R/O}

Fair arbitration (FA)                   : 0, 0, 0 {R/O}

Disconnect immediate (DImm)             : 0, 0, 0 {R/O}

Data transfer disconnect control (DTDC) : 0, 0, 0 {R/O}

First burst size (FBS)                  : 0, 0, 0 {R/O}

 

Control Mode                             : Page [0Ah] (Factory, Current, Saved)

Task set type (TST)                     : 0, 0, 0 {R/O}

Task mgmt only (TMF_ONLY)               : 0, 0, 0 {R/O}

Descriptor format (D_SENSE)             : 0, 0, 0 {R/O}

Global logging disable (GLTSD)          : 0, 0, 0 {R/O}

Report log excp. (RLEC)                 : 0, 0, 0

Queue alg. modifier (QAM)               : 0, 0, 0 {R/O}

Queue error mgmt (QERR)                 : 0, 0, 0 {R/O}

(DQUE)                                  : 0, 0, 0 {R/O}

(VS)                                    : 0, 0, 0 {R/O}

Report check (RAQ)                      : 0, 0, 0 {R/O}

Unit attn interlocks (UA_INTLCK)        : 0, 0, 0 {R/O}

Software write prot (SWP)               : 0, 0, 0 {R/O}

(RAERP)                                 : 0, 0, 0 {R/O}

(UUAERP)                                : 0, 0, 0 {R/O}

(EAERP)                                 : 0, 0, 0 {R/O}

App tag owner (ATO)                     : 0, 0, 0 {R/O}

Task aborted status (TAS)               : 0, 0, 0 {R/O}

Autoload mode (AUTOL)                   : 0, 0, 0 {R/O}

Ready AER holdoff period (RAER)         : 0, 0, 0 {R/O}

Busy timeout period (BTP)               : 65535, 65535, 65535 {R/O}

Extended self-test time (ESTCT)         : 0, 0, 0 {R/O}

 

Data Compression                         : Page [0Fh] (Factory, Current, Saved)

DCE                                     : 1, 0, 1

DCC                                     : 1, 1, 1 {R/O}

DDE                                     : 1, 1, 1

RED                                     : 0, 0, 0

Compression algorithm                   : 00000003h, 00000003h, 00000003h

Decompression algorithm                 : 00000000h, 00000003h, 00000000h

 

Tape Control                             : Page [10h] (Factory, Current, Saved)

Change active partition (CAP)           : 0, 0, 0

Change active format (CAF)              : 0, 0, 0 {R/O}

Active format                           : 0, 0, 0 {R/O}

Active partition                        : 0, 0, 0

Write buffer full ratio                 : 0, 0, 0 {R/O}

Read buffer empty ratio                 : 0, 0, 0 {R/O}

Write delay time (in 100ms)             : 0, 0, 0

Data buffer recovery (DBR)              : 0, 0, 0 {R/O}

Block identifiers supported (BIS)       : 1, 1, 1 {R/O}

Report setmarks (RSMK)                  : 1, 1, 1 {R/O}

Automatic velocity control (AVC)        : 0, 1, 1

Stop on consecutive filemarks (SOCF)    : 0, 0, 0 {R/O}

Recover buffer over (RBO)               : 0, 0, 0 {R/O}

Recover error warning (REW)             : 0, 0, 0 {R/O}

Gap size                                : 0, 0, 0 {R/O}

EOD Defined                             : 0, 0, 0 {R/O}

Enable EOD generation (EEG)             : 1, 1, 1 {R/O}

Synchronize early warning (SEW)         : 1, 1, 1 {R/O}

Soft write protect (SWP)                : 0, 0, 0 {R/O}

Buffer size at early warning            : 000000h, 000000h, 000000h

Data compression algorithm              : 00h, 00h, 00h

Associated write protect (ASOCWP)       : 0, 0, 0 {R/O}

Persistent write protect (PERSWP)       : 0, 0, 0 {R/O}

Permanent write protect (PRMWP)         : 0, 0, 0 {R/O}

 

Medium Partition                         : Page [11h] (Factory, Current, Saved)

Maximum additional partitions           : 35, 2, 35

Additional partitions defined           : 0, 0, 0

Fixed data partitions (FDP)             : 0, 0, 0

Select data partitions (SDP)            : 0, 0, 0 {R/O}

Initiator-defined partitions (IDP)      : 0, 0, 0

Partition size unit-of-measure (PSUM)   : 2, 2, 2

Partition on format (POFM)              : 0, 0, 0 {R/O}

CLEAR                                   : 0, 0, 0 {R/O}

ADDP                                    : 0, 0, 0 {R/O}

Medium format recognition               : 01h, 01h, 01h

Partition Units                         : 0, 0, 0

 

Informational Exceptions Control         : Page [1Ch] (Factory, Current, Saved)

PERF                                    : 0, 0, 0 {R/O}

EBF                                     : 0, 0, 0 {R/O}

EWASC                                   : 0, 0, 0 {R/O}

DExcpt                                  : 1, 1, 1 {R/O}

TEST                                    : 0, 0, 0

EBACKERR                                : 0, 0, 0 {R/O}

LogErr                                  : 0, 0, 0 {R/O}

MRIE                                    : 0, 0, 0 {R/O}

Interval timer                          : 00000000h, 00000000h, 00000000h

Report count                            : 00000000h, 00000000h, 00000000h

 

 

Program Ended.